Stereo roll core transformer
The three-phase magnetic circuit of the three-dimensional winding core transformer is in an ideal symmetrical state, and the three-phase no-load current and no-load voltage of the transformer are balanced and symmetrical, which reduces the distortion of the no-load current waveform and the third harmonic component, and improves the quality of power supply. There is no air gap in the core winding system, so that the no-load current, no-load loss and operating noise of the transformer are significantly reduced. The internal use of patent protection of innovative structure, transformer anti-short-circuit ability, is a more buried structure, better performance, higher reliability of the traditional transformer replacement products.
Safe and reliable
Well-made
After-sales worry-free
Quality Assurance
Classification:
6kV-15kV oil-immersed transformer
Telephone:86-371-63719330
Product Introduction
The three-phase magnetic circuit of the three-dimensional winding core transformer is in an ideal symmetrical state, and the three-phase no-load current and no-load voltage of the transformer are balanced and symmetrical, which reduces the distortion of the no-load current waveform and the third harmonic component, and improves the quality of power supply. There is no air gap in the core winding system, so that the no-load current, no-load loss and operating noise of the transformer are significantly reduced. The internal use of patent protection of innovative structure, transformer anti-short-circuit ability, is a more buried structure, better performance, higher reliability of the traditional transformer replacement products.
Compared with the GB6451-2008 standard (S9 type), the no-load loss of the three-dimensional winding core type 11 product is reduced by 28.879 on average, the no-load current is reduced by more than 80%, and the noise is reduced by 8dB (A)~ 11dB(A), which is lower than 50dB(A).
Compared with the GB6451-2008 standard (S9 type), the no-load loss of the three-dimensional coil core type 13 product is reduced by 50%, the no-load current is reduced by more than 80%, and the noise is reduced by 8dB(A)~ 11dB(A). Compared with S11 type transformer with the same capacity, the no-load loss is reduced by more than 25%, the no-load current is reduced by 70%, and the noise is reduced by 7dD(A)-10dD(A), low Ding 50dB(A).
Main implementation standards
GB1094、GB/T6451、JB/T3837、GB20052
Use of environmental conditions
1. Altitude ≤ 2500m
2. Maximum ambient temperature: 40 ℃
3. Maximum annual average temperature: 20 ℃
4. Maximum daily average temperature: 30 ℃
5. Minimum outdoor temperature: 30 ℃
Main technical parameters of S11-M-30 ~ 3150/10 oil-immersed distribution transformer
|
Model |
H-V |
VoltageCombination and tapScope High voltage tap range |
L-V |
Bonding group |
No-load loss |
Load loss |
No-load current current |
sound power Rate Level |
short circuit impedance circut |
Total Quality |
Long |
Overall dimension (mm) Wide |
High |
|
S11-M-30/10 |
6 6.3 10.5 11 |
± 2 × 2.5 |
0.4 |
Dyn11 |
0.10 |
0.63/0.6 |
2.0 |
50 |
4.0 |
280 |
730 |
450 |
995 |
|
S11-M-50/10 |
0.13 |
0.91/0.87 |
1.8 |
350 |
870 |
610 |
1005 |
||||||
|
S11-M-63/10 |
0.15 |
1.09/1.04 |
1.7 |
445 |
910 |
570 |
1080 |
||||||
|
S11-M-80/10 |
0.18 |
1.31/1.25 |
7.7 |
52 |
480 |
920 |
635 |
045 |
|||||
|
S11-M-100/10 |
0.20 |
1.58/1.50 |
1.6 |
550 |
825 |
665 |
150 |
||||||
|
S11-M-125/10 |
0.24 |
1.89/1.80 |
1.5 |
54 |
650 |
960 |
670 |
1180 |
|||||
|
S11-M-160/10 |
0.28 |
2.31/2.20 |
1.4 |
815 |
1010 |
730 |
1200 |
||||||
|
S11-M-200/10 |
0.34 |
2.73/2.60 |
1.3 |
56 |
970 |
1045 |
755 |
1240 |
|||||
|
S11-M-250/10 |
0.40 |
3.20/3.05 |
1.2 |
070 |
1080 |
800 |
1290 |
||||||
|
S11-M-315/10 |
0.48 |
3.83/3.65 |
1.1 |
58 |
1320 |
1120 |
840 |
1360 |
|||||
|
S11-M-400/10 |
0.57 |
4.52/4.30 |
1.0 |
1625 |
1170 |
900 |
1380 |
||||||
|
S11-M-500/10 |
0.68 |
5.14/5.15 |
1.0 |
60 |
1720 |
1195 |
960 |
1400 |
|||||
|
S11-M-630/10 |
0.81 |
6.20 |
0.9 |
4.5 |
2310 |
1470 |
1100 |
1600 |
|||||
|
S11- M300/1C |
0.98 |
7.50 |
0.8 |
62 |
2630 |
540 |
945 |
700 |
|||||
|
S11-M-1000/10 |
1.15 |
10.30 |
0.7 |
3030 |
1515 |
1150 |
1720 |
||||||
|
S11-M-1250/10 |
1.36 |
12.00 |
0.6 |
65 |
3405 |
2040 |
1220 |
1755 |
|||||
|
S11-M-1600/10 |
1.64 |
14.50 |
0.6 |
4110 |
2050 |
250 |
1944 |
||||||
|
S11-2000/10 |
2.05 |
20.90 |
0.5 |
5.0 |
4960 |
2180 |
2040 |
2340 |
|||||
|
S11-2500/10 |
2.50 |
25.00 |
0.4 |
67 |
5950 |
2335 |
2010 |
2435 |
|||||
|
S11-3150/10 |
3.10 |
33.00 |
0.4 |
70 |
7805 |
2510 |
2100 |
2510 |
Main technical parameters of S13-M-30 ~ 3150/10 oil-immersed distribution transformer
|
Model |
Voltage combination and tap range |
Bonding group Label |
no-load loss |
Load loss |
No-load current % |
sound power |
short circuit impedance Short- circut |
Total quality |
Overall dimension (mm) Out-LineDimentaion |
||||
|
Long |
Wide mm |
High |
|||||||||||
|
S13-M-30/10 |
6 10 |
±2x2.5 |
0.4 |
Dyn11 |
0.08 |
0.63/0.60 |
1.6 |
50 |
4.0 |
290 |
810 |
450 |
1010 |
|
S13-M-50/10 |
0.10 |
0.91/0.87 |
1.6 |
395 |
885 |
615 |
1055 |
||||||
|
S13-M-63/10 |
0.11 |
1.09/1.04 |
1.5 |
560 |
940 |
680 |
1125 |
||||||
|
S13-M-80/10 |
0.13 |
1.31/1.25 |
1.5 |
52 |
565 |
930 |
635 |
1140 |
|||||
|
S13-M-100/10 |
0.15 |
1.58/1.50 |
1.4 |
630 |
790 |
715 |
155 |
||||||
|
S13-M-125/10 |
0.17 |
1.89/1.80 |
1.3 |
54 |
775 |
900 |
680 |
1235 |
|||||
|
S13-M-160/10 |
0.20 |
2.31/2.20 |
1.3 |
910 |
945 |
830 |
1255 |
||||||
|
|
0.24 |
2.73/2.60 |
1.2 |
56 |
1055 |
960 |
820 |
1275 |
|||||
|
S13-M-250/10 |
0.29 |
3.20/3.05 |
1.1 |
1180 |
990 |
830 |
330 |
||||||
|
S13-M-315/10 |
0.34 |
3.83/3.65 |
1.1 |
58 |
1415 |
1035 |
925 |
1395 |
|||||
|
S13-M- |
0.41 |
4.52/4.30 |
1.0 |
1635 |
1485 |
1015 |
1385 |
||||||
|
S13-M-500/10 |
0.48 |
5.41/5.15 |
0.9 |
60 |
2155 |
1160 |
975 |
1605 |
|||||
|
S13-M-630/10 |
0.57 |
6.20 |
0.8 |
4.5 |
2385 |
1650 |
1185 |
1455 |
|||||
|
S13-M-800/10 |
0.70 |
7.50 |
0.8 |
62 |
3290 |
1560 |
920 |
1900 |
|||||
|
S13-M-1000/10 |
0.83 |
10.30 |
0.8 |
3540 |
1040 |
1075 |
2045 |
||||||
|
S13-M-1250/10 |
0.97 |
12.00 |
0.7 |
65 |
3950 |
1690 |
1015 |
2015 |
|||||
|
S13-M-1600/10 |
1.17 |
14.50 |
0.6 |
AQA0 |
11805 |
11250 |
|
||||||
|
S13-2000/10 |
1.82 |
20.90 |
0.4 |
5.0 |
5950 |
2310 |
2140 |
2460 |
|||||
|
S132500/10 |
2.40 |
25.00 |
0.4 |
67 |
7275 |
2480 |
2200 |
2570 |
|||||
|
S13-3150/10 |
2.48 |
33.00 |
0.4 |
70 |
9360 |
2670 |
2340 |
2700 |
|||||
Note: The above are the national standard performance parameters. According to user needs, our company can provide products with different performance parameters.
For transformers of 500kVA and below, the load loss value on the slash in the table is applicable to D: connection group. The load loss below the slash applies to the 0 bonding group.
Our company produces on-load voltage regulation products according to user needs.
The total mass and external dimensions of the transformer are for reference only, and the actual dimensions are subject to the external drawings of the transformer.
Three-dimensional winding core transformer appearance drawing


Key words:
Stereo roll core transformer