S(F)S11-6300 ~ 80000/110 Three-phase Three-winding Non-excitation Voltage-regulating Power Transformer
+
  • S(F)S11-6300 ~ 80000/110 Three-phase Three-winding Non-excitation Voltage-regulating Power Transformer

S(F)S11-6300 ~ 80000/110 Three-phase Three-winding Non-excitation Voltage-regulating Power Transformer

Main implementation standards: GB1094, GB/T6451, JB/13837, GB24790

Safe and reliable

Well-made

After-sales worry-free

Quality Assurance

Classification:

66kV-220kV oil-immersed power transformer

Telephone:86-371-63719330

Product Introduction

Use of environmental conditions

1. Altitude ≤ 2500m

2. Maximum ambient temperature: 40 ℃

3. Maximum annual average temperature: 20 ℃

4. Maximum daily average temperature: 30 ℃

5. Minimum outdoor temperature: -30 ℃

Main implementation standards

GB1094、GB/T6451、JB/13837、GB24790

Transformer insulation level

L | 480AC200-L | 325AC140/L | 200 AC85/L | 175AC35

(LV 10kV level)

L | 480AC200-L | 325AC140/L | 200 AC85/L | 60AC25

(LV 6kV level)

Main technical parameters

 

Model
Type

voltage combination
High pressure
H-V
kN

and tap range

 

Join Group Label
Cnnnovynn car kit
symbo

 

No-load loss No-Load
loss
kW

Load loss
Load loss
(75)kW
%

No-load current

 No-load current
%

 

short circuit impedance
Short-circuit impedance
(%)

MV H-V
1N

Low pressure
L-V
kV

S(F)S11-6300/110

 

 

 

 

110 ± 2 × 2.5

121 ± 2 × 2.5

 

 

 

 

35
37  38.5

 

 

 

6.3
6.6
10.5
11

 

 

 

 

YNyn0d11

8.96

44.65

0.74

 

 

 

High-Medium
17.5~18.5
High-Low
10.5
medium-low
6.5

 

 

 

High-Medium
10.5
High-Low
17.5~18.5 Medium-Low
6.5

S(F)S11-8000/110

10.64

53.20

0.70

S(F)S11-10000/110

12.64

62.70

0.67

S(F)S11-12500/110

14.72

74.10

0.63

S(F)S11-16000/110

17.92

90.25

0.59

S(F)S11-20000/110

21.12

106.40

0.58

S(F)S11-25000/110

24.64

126.35

0.54

S(F)S11-315001110

29.44

149.15

0.54

S(F)S11-40000/110

34.88

179.55

0.50

S(F)S11-50000/110

41.60

213.75

0.50

S(F)S11-63000/110

49.28

256.50

0.45

S(F)S11-80000/110

58.32

320.00

0.30

Note: The above are the national standard performance parameters. According to user needs, our company can provide products with different performance parameters.

Capacity allocation of high, medium and low voltage winding groups is 100/100/100%

As required, the linkage group is labeled YNdllyo.

According to user needs, our company can provide self-cooling products, can also provide other voltage combinations of products.

Model
ype

Total mass
L0a
(kg)

Exterior dimensions (mm)Oul-Line Dimentaion

L

B

H

HL

A1

A2

S(F)S11-6300/110

28340

5350

4075

4515

6700

1475

1475

S(F)S11-8000/110

31250

5390

4230

4620

6770

2040

1475

S(F)S11-10000/110

35280

5780

4285

5245

7280

1640

1475

S(F)S11-12500/110

40095

5840

4390

5290

7430

1640

1475

S(F)S11-16000/110

47600

5925

4560

5350

7640

2040

1475

S(F)S11-20000/110

50020

6010

4430

5340

8050

2040

1475

S(F)S11-25000/110

58350

6200

4745

5570

8080

2040

1475

S(F)S11-31500/110

67515

6325

5170

5655

8460

2040

1475

S(F)S11-40000/110

79000

6700

5230

5700

8800

2500

1475

S(F)S11-50000/110

91630

6730

5330

5760

9530

2500

1475

S(F)S11-63000/110

102200

6870

5470

5810

10200

2500

1500

S(F)S11-80000/110

125800

7210

5600

6120

12010

2500

1500

Note: The total mass and external dimensions of the transformer are for reference only, and the actual dimensions are subject to the external drawings of the transformer.

Key words:

S(F)S11-6300 ~ 80000/110 Three-phase Three-winding Non-excitation

Related Products

Related Products

Product Consulting