S11 type 10kV oil-immersed transformer
S11 type 10kV oil-immersed transformer
S11 type 10kV oil-immersed transformer
S11 type 10kV oil-immersed transformer
S11 type 10kV oil-immersed transformer
+
  • S11 type 10kV oil-immersed transformer
  • S11 type 10kV oil-immersed transformer
  • S11 type 10kV oil-immersed transformer
  • S11 type 10kV oil-immersed transformer
  • S11 type 10kV oil-immersed transformer

S11 type 10kV oil-immersed transformer

S11 series oil-immersed transformer, is a traditional structure, compact product structure, high reliability transformer products. The product is widely used in urban and rural power grid construction and renovation projects. This product is particularly suitable for areas where power is insufficient, load fluctuations are large, and routine maintenance is difficult. Since the transformer adopts a fully sealed structure to avoid contact between transformer oil and air, it can operate in a humid environment and is an ideal distribution equipment in the vast distribution network in urban and rural areas.

Safe and reliable

Well-made

After-sales worry-free

Quality Assurance

Classification:

6kV-15kV oil-immersed transformer

Telephone:86-371-63719330

Product Introduction

S11 series oil-immersed transformer, is a traditional structure, compact product structure, high reliability transformer products. This series of products adopts fully sealed oil tank to isolate transformer oil from air and slow down the aging of transformer oil and insulation parts.

The product is widely used in urban and rural power grid construction and renovation projects. This product is particularly suitable for areas where power is insufficient, load fluctuations are large, and routine maintenance is difficult. Since the transformer adopts a fully sealed structure to avoid contact between transformer oil and air, it can operate in a humid environment and is an ideal distribution equipment in the vast distribution network in urban and rural areas.

Main technical parameters

Model

Type

voltage combination

Voltage combination

Bonding Group Label

connection

symbol

short circuit impedance

Short-circuit

impedance

Loss(W)

No-load current

No-load

current(%)

High pressure

H-V

tap range

Tapping

range

Low pressure

L-V

No-load loss

No-load

loss

Load loss

Load loss

S11-M-30

15

13.5

11

10.5

10

6.3

6

± 5% ± 2 × 2.5%

0.4

0.69

Yyn0

Dyn11

4.0  100 630/600 2.3 
S11-M-50 130 910/870 2.0 
S11-M-80 180 1310/1250 1.9 
S11-M-100 200 1580/1500 1.8 
S11-M-125 240 1890/1800 1.7 
S11-M-160 280 2310/2200 1.6 
S11-M-200 340 2730/2600 1.5 
S11-M-250 400 3100/3050 1.4 
S11-M-315 480 3830/3650 1.4 
S11-M-400 570 4520/4300 1.3 
S11-M-500 680 5410/5100 1.2 
S11-M-630 810 6200 1.1 
S11-M-800 4.5 980 7500 1.0 
S11-M-1000 1150 10300 1.0 
S11-M-1250 1360 12800 0.9 
S11-M-1600 1640 14500 0.8 
S11-M-2000 5.0  2050 17820 0.6 
S11-M-2500 2340 20700 0.6 

 

Key words:

S11 type 10kV oil-immersed transformer

Related Products

Related Products

Product Consulting