S11(13)-50~3150/35 Oil-immersed Distribution Transformer
+
  • S11(13)-50~3150/35 Oil-immersed Distribution Transformer

S11(13)-50~3150/35 Oil-immersed Distribution Transformer

35KV grade oil-immersed power transformer adopts new materials, new technology, new structure, optimized design and meticulous manufacturing. The core material is made of high-quality silicon steel sheet with high magnetic permeability and low loss. The structure is a rigid frame structure with good stability, low noise and strong short-circuit resistance.

Safe and reliable

Well-made

After-sales worry-free

Quality Assurance

Classification:

20kV-35kV oil-immersed transformer

Telephone:86-371-63719330

Product Introduction

◆ 35KV grade oil-immersed power transformer adopts new materials, new technology, new structure, optimized design and meticulous manufacturing

◆ The core material is made of high-quality silicon steel sheet with high magnetic permeability and low loss. The structure is a rigid frame structure with good stability, low noise and strong short-circuit resistance.

The winding adopts high quality oxygen free copper wire, good conductivity, low load loss. The winding is designed as an advanced longitudinal oil channel structure, with good heat dissipation effect, high electrical insulation strength and good impact resistance.

◆ The body is pressed by high-strength electrical laminate, all leads are firmly clamped, and the structure is scientific and reasonable.

◆ Plateau reinforced casing, suitable for high altitude areas.

The series transformer set up a full range of protection device, good technical performance, reliable operation.

Main technical parameters

 

Model
Type

Voltage combination and tap range
Vollage combines

 

 

Low pressure

L-V

KV

 

Bonding group
Label
symbo

 

No-load loss

 No-Load
loss
kW

 

Load loss
Load loss
(75°)
kW

No-load current
No-load
current
%

short circuit resistance
resistance
Short-
circut
mpedance
%

High pressure

H-V

KV

High voltage tap

Scope
H-V
Tanning range

S11-50/35

 

 

 

 

 

 

 

35

38.5

 

 

 

 

 

 

 

± 2 × 2.5
±5

 

 

 

 

 

 

 

0.4

 

 

 

 

 

Dyn11

 

 

 

 

 

Yyn0

0.17

1.21/1.15

1.6

 

 

 

 

 

6.5

S11-63/35

0.20

1.49/1.42

1.5

S11-80/35

0.22

1.75/1.67

1.4

S11-100/35

0.23

2.01/1.92

1.4

S11-125/35

0.27

2.38/2.26

1.3

S11-160/35

0.29

2.82/2.69

1.3

S11-200/35

0.34

3.33/3.16

1.2

S11-250/35

0.41

3.95/3.76

1.1

S11-315/35

0.49

4.76/4.53

1.1

S11-400/35

0.58

5.75/5.47

1.0

S11-500/35

0.69

6.92/6.58

1.0

S11-630/35

0.83

7.87

0.9

S11-800/35

0.98

9.41

0.8

S11-1000/35

1.15

11.54

0.7

S11-1250/35

1.41

13.94

0.6

S11-1600/35

1.70

16.67

0.5

S11-2000/35

2.18

20.90

0.5

S11-2500/35

2.80

27.60

0.4

S11-3150/35

3.14

34.00

0.4

 

Note: The above are the national standard performance parameters. According to user needs, our company can provide products with different performance parameters.

For 500kVA and below transformers, the load loss values above the mid-slope apply to the Dyn11 connection group and the load loss below the slope apply to the YynO connection group.

 

Main technical parameters

 

Model
Type


High pressure

H-V

kV

Voltage combination and tap range

High voltage tap
Scope
H-V
Tapping range


Low pressure
L-V

kV

 

Bonding group

Label
symbul

No-load loss
No-Load
loss
kW

 

Load loss

Load loss
(75°)
KW

 

No-load current

No-load 

Current
%

 

short circuit impedance
Shart-
circuit
mpedance
%

S13-50/35

 

 

 

 

 

 

 

 

35

38.5

 

 

 

 

 

 

 

 

± 2 × 2.5
±5

 

 

 

 

 

 

 

 

0.4

 

 

 

 

 

Dyn11

 

 

 

 

YynO

0.13

1.21/1.15

1.6

 

 

 

 

 

6.5

S13-63/35

0.15

1.49/1.42

1.5

S13-80/35

0.16

1.75/1.67

1.4

S13-100/35

0.17

2.01/1.92

1.4

S13-125/35

0.20

2.38/2.26

1.3

S13-160/35

0.22

2.82/2.69

1.3

S13-200/35

0.26

3.33/3.16

1.2

S13-250/35

0.31

3.95/3.76

1.1

S13-315/35

0.37

4.76/4.53

1.1

S13-400/35

0.44

5.75/5.47

1.0

S13-500/35

0.52

6.92/6.58

1.0

S13-630/35

0.62

7.87

0.9

S13-800/35

0.74

9.41

0.8

S13-1000/35

0.86

11.54

0.7

S13-1250/35

1.06

13.94

0.6

S13-1600/35

1.27

16.67

0.5

S13-2000/35

1.63

20.90

0.5

S13-2500/35

1.92

27.60

0.4

S13-3150/35

2.28

30.40

0.4

Note: The above are the national standard performance parameters. According to user needs, our company can provide products with different performance parameters.

For 500kVA and below transformers, the load loss values above the mid-slope apply to the Dyn11 connection group and the load loss below the slope apply to the YynO connection group.

The total mass and external dimensions of the transformer are for reference only, and the actual dimensions are subject to the external drawings of the transformer.