S(F)SZ11-6300 ~ 80000/110 Three-phase Three-winding On-load Voltage-regulating Power Transformer
The main implementation of the standard GB1094, GB/T6451, JB/13837, GB24790
Safe and reliable
Well-made
After-sales worry-free
Quality Assurance
Classification:
66kV-220kV oil-immersed power transformer
Telephone:86-371-63719330
Product Introduction
Use of environmental conditions
1. Altitude ≤ 2500m
2. Maximum ambient temperature: 40 ℃
3. Maximum annual average temperature: 20 ℃
4. Maximum daily average temperature: 30 ℃
5. Minimum outdoor temperature: -30 ℃
Main implementation standards
GB1094、GB/T6451、JB/13837、GB24790
Transformer insulation level
L | 480AC200-L | 325AC140/L | 1200 AC85/L | 175AC35
(Low H voltage 10kV level)
L | 480AC200-L | 325AC140/L | 1200 AC85/L | 60AC25
(LV GkV level)
Main technical parameters
Model |
Voltage combination and tap range |
Join Group Label |
No-load loss |
Load loss |
No-load current |
short circuit impedance |
||
High pressure |
Medium pressure |
Low pressure |
||||||
S(F)SZ11-6300/11C |
110 ± 8 × 12.5 |
35 |
6.3 |
YNyn0d11 |
9.60 |
44.65 |
0.86 |
High-Medium |
S(F)SZ11-8000/110 |
11.52 |
53.20 |
0.86 |
|||||
S(F)SZ11-10000/110 |
13.68 |
62.70 |
0.80 |
|||||
S(F)SZ11-12500/110 |
16.16 |
74.10 |
0.80 |
|||||
S(F)SZ11-16000/110 |
19.36 |
90.25 |
0.76 |
|||||
S(F)SZ11-20000/110 |
22.88 |
106.40 |
0.76 |
|||||
S(F)SZ11-25000/110 |
27.04 |
126.35 |
0.70 |
|||||
S(F)SZ11-31500/110 |
32.16 |
149.15 |
0.70 |
|||||
S(F)SZ11-40000/110 |
38.56 |
179.55 |
0.66 |
|||||
S(F)SZ11-50000/11C |
45.52 |
213.75 |
0.66 |
|||||
S(F)SZ11-63000/110 |
54.16 |
256.50 |
0.60 |
|||||
S(F)SZ11-80000/110 |
64.80 |
320.00 |
0.50 |
Note: The above are the national standard performance parameters. According to user needs, our company can provide products with different performance parameters.
Capacity allocation of high, medium and low voltage winding groups is 100/100/100%
As required, the linkage group is labeled YNd11y0.
According to user needs, our company can provide self-cooling products, can also provide other voltage combinations of products.
Model |
Total mass |
Outside dimensions (mm)Out Line Dimentaion |
|||||
L |
B |
H |
HL |
A1 |
A2 |
||
S(F)SZ11-6300/110 |
28430 |
6390 |
3950 |
4390 |
6300 |
2040 |
1475 |
S(F)SZ11-8000/110 |
30350 |
6420 |
3950 |
4430 |
6300 |
2040 |
1475 |
S(F)SZ11-10000/110 |
35280 |
6620 |
3580 |
4810 |
6300 |
2040 |
1475 |
S(F)SZ11-12500/110 |
41330 |
6900 |
3615 |
4920 |
6300 |
2040 |
1475 |
S(F)SZ11-16000/110 |
48050 |
7085 |
4300 |
5040 |
6350 |
2040 |
1475 |
S(F)SZ11-20000/110 |
51500 |
6700 |
4370 |
5020 |
6800 |
2040 |
1475 |
S(F)SZ11-25000/110 |
60030 |
7220 |
4420 |
5500 |
8400 |
2040 |
1475 |
S(F)SZ11-31500/110 |
69645 |
7250 |
4450 |
5580 |
8400 |
2040 |
1475 |
S(F)SZ11-40000/110 |
83910 |
7265 |
4500 |
5600 |
8450 |
2500 |
1475 |
S(F)SZ11-50000/110 |
93185 |
7300 |
4800 |
5800 |
8500 |
2500 |
1475 |
S(F)SZ11-63000/110 |
106625 |
7340 |
4985 |
6000 |
8600 |
2500 |
1475 |
S(F)SZ11-80000/110 |
137500 |
7700 |
5500 |
6780 |
9200 |
2500 |
1475 |
Note: The total mass and external dimensions of the transformer are for reference only, and the actual dimensions are subject to the external drawings of the transformer.
Key words:
S(F)SZ11-6300 ~ 80000
Related Products
Related Products
Product Consulting