Product Introduction

Use of environmental conditions

1. Altitude ≤ 2500m

2. Maximum ambient temperature: 40 ℃

3. Maximum annual average temperature: 20 ℃

4. Maximum daily average temperature: 30 ℃

5. Minimum outdoor temperature: -30 ℃

Main implementation standards

GB1094、GB/T6451、JB/13837、GB24790

Transformer insulation level

L | 480AC200-L | 325AC140/L | 1200 AC85/L | 175AC35

(Low H voltage 10kV level)

L | 480AC200-L | 325AC140/L | 1200 AC85/L | 60AC25

(LV GkV level)

Main technical parameters

 

Model
Type

Voltage combination and tap range
Voltage combination(kV)

 

Join Group Label
Connectior symbol

 

No-load loss
No-Load loss
kW

 

Load loss
Load loss
(75°)kW
%

 

No-load current
No-load
current
%

 

short circuit impedance
Short-circuit
impedance
(%)

High pressure
H-V    KV

Medium pressure
H-V
kV

Low pressure
L-V
kV

S(F)SZ11-6300/11C

 

 

 

 

110 ± 8 × 12.5

 

 

 

 

35
37
38.5

 

 

 

6.3
6.6
10.5
11

 

 

 

 

YNyn0d11

9.60

44.65

0.86

 

 

 

High-Medium
10.5
High-Low
17.5~18.5 Medium-Low
0,

S(F)SZ11-8000/110

11.52

53.20

0.86

S(F)SZ11-10000/110

13.68

62.70

0.80

S(F)SZ11-12500/110

16.16

74.10

0.80

S(F)SZ11-16000/110

19.36

90.25

0.76

S(F)SZ11-20000/110

22.88

106.40

0.76

S(F)SZ11-25000/110

27.04

126.35

0.70

S(F)SZ11-31500/110

32.16

149.15

0.70

S(F)SZ11-40000/110

38.56

179.55

0.66

S(F)SZ11-50000/11C

45.52

213.75

0.66

S(F)SZ11-63000/110

54.16

256.50

0.60

S(F)SZ11-80000/110

64.80

320.00

0.50

Note: The above are the national standard performance parameters. According to user needs, our company can provide products with different performance parameters.

Capacity allocation of high, medium and low voltage winding groups is 100/100/100%

As required, the linkage group is labeled YNd11y0.

According to user needs, our company can provide self-cooling products, can also provide other voltage combinations of products.

 

Model
Type

Total mass
Total
(Kg)

Outside dimensions (mm)Out Line Dimentaion

L

B

H

HL

A1

A2

S(F)SZ11-6300/110

28430

6390

3950

4390

6300

2040

1475

S(F)SZ11-8000/110

30350

6420

3950

4430

6300

2040

1475

S(F)SZ11-10000/110

35280

6620

3580

4810

6300

2040

1475

S(F)SZ11-12500/110

41330

6900

3615

4920

6300

2040

1475

S(F)SZ11-16000/110

48050

7085

4300

5040

6350

2040

1475

S(F)SZ11-20000/110

51500

6700

4370

5020

6800

2040

1475

S(F)SZ11-25000/110

60030

7220

4420

5500

8400

2040

1475

S(F)SZ11-31500/110

69645

7250

4450

5580

8400

2040

1475

S(F)SZ11-40000/110

83910

7265

4500

5600

8450

2500

1475

S(F)SZ11-50000/110

93185

7300

4800

5800

8500

2500

1475

S(F)SZ11-63000/110

106625

7340

4985

6000

8600

2500

1475

S(F)SZ11-80000/110

137500

7700

5500

6780

9200

2500

1475