Combined transformer (American box transformer)
ZGS series combined transformer is American transformer, which is a series of products developed according to the development and transformation of urban and rural power grid construction. It is a transformer body, switchgear, fuses, tap-switches, low-voltage distribution devices and other corresponding auxiliary equipment combination of transformers, to meet the user energy metering, reactive power compensation, low-voltage shunt and other preparation requirements.
Safe and reliable
Well-made
After-sales worry-free
Quality Assurance
Classification:
Box-type substation
Telephone:86-371-63719330
Product Introduction
ZGS series combined transformer is American transformer, which is a series of products developed according to the development and transformation of urban and rural power grid construction. It is a transformer body, switchgear, fuses, tap-switches, low-voltage distribution devices and other corresponding auxiliary equipment combination of transformers, to meet the user energy metering, reactive power compensation, low-voltage shunt and other preparation requirements.
ZGS type combined transformer as AC 50/60HZ, 6 ~ 11kV power grid, rated capacity of 80 ~ 1600kVA independent sets of power transformation and distribution device, used for outdoor. Widely used in industrial parks, urban residential areas, commercial centers, high-rise buildings and temporary construction sites and other places.
Product Features
1. Small body volume, high-end, small, easy-to-wear
2. Low loss, low noise, low temperature rise, strong overload capacity, strong ability to resist sudden short circuit.
3. Fully enclosed, fully insulated structure, safe and reliable operation.
4. The wiring method is flexible, which can be used in both the terminal system and the ring network system, which is convenient for conversion and improves the reliability of power supply.
5. Convenient operation, convenient maintenance, short production cycle and low project cost.
Primary Wiring Diagram of Combined Transformer (Terminal Type)
Typical Power Distribution Scheme of Combined Transformer
Serial Number |
Transformer capacity |
Switch selection |
Main Configuration |
|
1 |
50~500kVA |
Master switch 100 ~ 1000A |
Main switch:100~1000A |
Total metering, main switch, voltmeter |
2 |
630~800kVA |
The main switch 100 ~ 1250A outlet switch 100A ~ 800A |
Main switch:100~1250A |
Total metering, main switch, voltmeter |
3 |
1000~1600kVA |
Master switch 100 ~ 2500A |
Main switch:100~2500A |
Total metering, main switch, voltmeter |